Rules for the Classification of
Mobile Offshore Units
RB-01-E
Section 1 General
Section 2 Definitions
CHAPTER 2 CLASSIFICATION AND SURVEYS
Section 1 General
Section 2 Classification
Section 3 Surveys
CHAPTER 3 HULL CONSTRUCTION AND EQUIPMENT
Section 1 General
Section 2 Materials
Section 3 Welding
Section 4 Ice Strengthening
Section 5 Corrosion Control
Section 6 Fire Protection, Means of Escape and Fire Detection & Extinction
Section 7 Guardrails and Bulwarks
Section 8 Temporary or Emergency Mooring Equipment
Section 9 Access
Section 10 Towing Arrangements
Section 11 Protective Coatings of Dedicated Seawater Ballast Tanks
Section 12 Anti-fouling Systems
Section 13 Drainage and Sediment Control
CHAPTER 4 DESIGN CONDITION
Section 1 Design Loads
Section 2 Calculation of Strength
Section 3 Analysis of Overall Strength
Section 4 Scantlings of Structural Members
Section 5 Helicopter Deck
Section 6 Position Keeping Systems and Components
CHAPTER 5 TYPE OF UNITS
Section 1 Self-elevating Units
Section 2 Column-stabilized Units
Section 3 Surface Type Units
CHAPTER 6 WATERTIGHT INTEGRITY
Section 1 Watertight Bulkheads
Section 2 Closing Appliances
CHAPTER 7 STABILITY
Section 1 General Requirements of Stability
Section 2 Stability Criterion under Wind Force
CHAPTER 8 HAZARDOUS AREA
Section 1 General
Section 2 Extent of Hazardous Area
Section 3 Ventilation
CHAPTER 9 FIRE PROTECTION, MEANS OF ESCAPE AND FIRE EXTINCTION
Section 1 General
Section 2 Fire Protection and Means of Escape
Section 3 Fire Detection and Extinction
1. Spaces having a fire risk, in principle, are to be provided with an automatic alarm system.
3. The fire detection main indicator board is to be at a manned control station and is to be clearly to indicate where fire has been detected.
7. Sufficient manual fire alarm stations are to be installed throughout the accommodation spaces, service spaces and control stations. One manually operated call point is to be located at each exit. Manually operated call points are to be readily accessible in the corridors of each deck such that no part of the corridor is more than 20 m from a manually operated call point. Measures are to be taken to prevent inadvertent operation of the manual call alarm system.
Section 4 Fire Extinguishing Systems for Helicopter Facilities
(5) the fire fighting systems equipment as given in 402. are to be provided and so arranged as to adequately protect both the helicopter deck and fuel storage areas.
Section 5 Gas cylinders
Section 6 Offshore Accommodation Unit
CHAPTER 10 MACHINERY INSTALLATIONS AND ELECTRICAL EQUIPMENT
Section 1 Machinery Installations and Electrical Equipment for Units
Section 2 Machinery Installations and Electrical Equipment for Self-propelled Units
CHAPTER 11 SPECIFIC OFFSHORE UNIT TYPES
Section 1 Offshore Crane Units
Section 2 Offshore Accommodation Units
Section 3 Floating Piers
Section 4 Offshore Plant Units